Whittlesea Building
Inspections

Frame inspection in Whittlesea

The structure before the walls get covered up and the roof gets battened.

  • After wall frame erection and bracing, before lining
  • 1 to 2 hours on site
  • Report within 24 hours
Get a quoteLeave your details here and we will send you a price

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

Stage3 of 7
When to bookAfter wall frame erection and bracing, before lining
Time on site1 to 2 hours on site
Inspected againstAS 1684 (timber framing), AS 4100 or NASH for steel frames, the engineer's bracing and tie-down plan, NCC Part 3.4

What is included in a Whittlesea frame inspection

  • Stud, plate, lintel and beam sizes against AS 1684 and the engineer's drawings
  • Wall straightness and plumb, top plate level
  • Floor level across the slab
  • Bracing type, position and fixing against the bracing plan
  • Tie-downs from roof to wall and wall to slab
  • Triple grips, straps and bolt fixings
  • Jack studs, lintels and trimmers over every opening
  • Window sill trimmers for wide openings
  • Roof truss spacing, fixing and girder connections
  • Valley boards, ceiling battens and roof bracing
  • Window and door openings against the plans
  • Wet area framing, noggings and service penetrations
  • Damaged, split, notched or over-drilled members
  • Termite collars and slab penetrations still visible
Why it matters here

Frame inspections on Whittlesea builds

Whittlesea frame inspections reveal the ordinary consequences of trades working quickly around each other. Timber tie downs short of engineering specs on a double storey. Steel straps missing off the ledger. Trusses not correctly fixed at the ridge. A lintel sitting crooked. Small defects do not stop construction, but fixing them early avoids future issues once trades arrive.

What we find at this stage in Whittlesea

  • Timber tie downs short of engineering specs
  • Steel straps missing off the ledger
  • Trusses not correctly fixed at the ridge
  • Lintel sitting crooked
  • Wall framing not plumb
Noggings around bath, recorded during a frame inspection in Beveridge
The inspector found noggings missing around the bath hob because the stud spacing exceeds 300mm, Beveridge
Sample findings

Sample defects found during our frame inspections in Whittlesea

Annotated findings from Frame inspections.

Noggins to garage ceiling, recorded during a frame inspection in Beveridge
Noggings are needed in the garage ceiling for the future door operator, Beveridge
Nogging unsecure, recorded during a frame inspection in Beveridge
The nogging above the meter box is not secure, Beveridge
Nogging around meter box, recorded during a frame inspection in Beveridge
Nogging around the meter box means timber framing is touching the electrical box, Beveridge
Missing, recorded during a frame inspection in Beveridge
One or more nogging pieces are missing from the wall framing, Beveridge

The other stages of a Whittlesea build

  1. Bored piers inspection in Whittlesea1Bored piersAfter drilling and cage placement, before concrete
  2. Slab pre-pour inspection in Whittlesea2Slab pre-pourThe day before pouring, before waterproofing
  3. Lock-up (pre-plaster) inspection in Whittlesea4Lock-up (pre-plaster)After roof cladding and external doors, before plasterboard
  4. Fixing inspection in Whittlesea5FixingAfter joinery and doors installed, before painting
  5. Waterproofing inspection in Whittlesea6WaterproofingAfter membrane application and prior to tiling
  6. Pre-handover (PCI) inspection in Whittlesea7Pre-handover (PCI)Two to three weeks prior to handover

All construction stage inspections in Whittlesea →

Guides

Construction stage guides for Whittlesea

All guides →

Book a frame inspection in Whittlesea

Instant online pricing for Whittlesea, or contact the booking team.

FAQ

Frame inspections in Whittlesea: common questions

Is the structure tied down correctly?

The engineering details must show how the roof ties to the walls and the walls attach to the slab. A frame inspection checks the timber structure against the approved plans and engineering documents.

Why do loose trusses matter at frame stage?

A truss that is not fixed to the ledger or the ridge can move under wind loads and damage the roof sheeting. It is a safety issue that must be resolved before the roof is fully secured.

How long does a standard inspection take?

A standard inspection on a single level takes around two to three hours. The time will be longer on a double storey because the inspector must safely access the upper frame and its fixings.

Are the defects actually fixable?

Timber was once the main industry. The inspection findings are outlined in a detailed document with images and precise site locations.

Want a second opinion?

A detailed report can save you from costly repairs later. We check the frame is done at lock-up. We mark every item as fixed, in progress or not done.

Are services inspected at this stage?

We mark visible defects like a pipe that is not capped or a point installed in the wrong spot. Check the site once all plumbing and electrical services are in before the next stage of construction.

Get a Free Quote